Air Conditioner BTU Calculator - AC Size for a Room
Air conditioner BTU calculator
| ft² | m² | BTU/h |
|---|---|---|
| 100–150 | 9.3–13.9 | 5,000 |
| 150–250 | 13.9–23.2 | 6,000 |
| 250–300 | 23.2–27.9 | 7,000 |
| 300–350 | 27.9–32.5 | 8,000 |
| 350–400 | 32.5–37.2 | 9,000 |
| 400–450 | 37.2–41.8 | 10,000 |
| 450–550 | 41.8–51.1 | 12,000 |
| 550–700 | 51.1–65 | 14,000 |
| 700–1,000 | 65–92.9 | 18,000 |
| 1,000–1,200 | 92.9–111.5 | 21,000 |
| 1,200–1,400 | 111.5–130.1 | 23,000 |
| 1,400–1,500 | 130.1–139.4 | 24,000 |
| 1,500–2,000 | 139.4–185.8 | 30,000 |
| 2,000–2,500 | 185.8–232.3 | 34,000 |
Step by step
- Table value for the area 215.3 ft² (20 m²) → 6,000 BTU/h
- Ceiling above 8 ft (2.44 m) 6,000 × 1.025 = 6,152 BTU/h
- Sunlight 6,152 × 1.1 = 6,767 BTU/h
- People above two and kitchen
- Convert to kW 6,767 ÷ 3,412.14 = 1.98 kW
This is an estimate, not a load calculation. Below 100 ft² (9.3 m²) the smallest row is used. Insulation, glazing, climate and top floors are not included; an installer can measure them.
Where the estimate comes from
The base figure is taken from the room air conditioner sizing table that the US ENERGY STAR programme publishes for 8 ft (2.44 m) ceilings. This calculator is independent: it is not endorsed by or affiliated with ENERGY STAR.
Formula
The rule step by step
T(A) is the table value for area A in square feet, H the ceiling height in feet (never below 8), s the sunlight factor and n the number of people. The row 100 to 150 ft² (9.3 to 13.9 m²) gives 5,000 BTU/h and the last one, 2,000 to 2,500 ft² (185.8 to 232.3 m²), gives 34,000. Add 10 percent for a very sunny room or take off 10 percent for a heavily shaded one; add 600 for each person above two and 4,000 for a kitchen.
Ceiling height
The table assumes an 8 ft (2.44 m) ceiling. Above that we scale the base figure with the extra air volume. This correction is our own simplification and is not part of the table.
Bigger is not always better
A unit that is too large cools quickly and switches off before it has removed enough moisture, so the room feels clammy. A unit that is too small runs without pause on hot days.